Windows 7 and version 2.1.8 Smart Control Resource Manager

by Centurion Technologies 22. July 2011 13:57

 

Due to many improvements made to speed up the TCP/IP communication in Smart Control Resource Manger the service is now loading much faster. Unfortunately, we have found that in some cases when rebooting, Smart Controls running version 2.1.8 on Windows 7 our service may be loading faster that the TCP/IP connection can handle. There is a simple solution to this problem. Windows 7 Smart Controls may need to slow down the service start up type to allow for the IP address to be registered in the service. To do this open the Service Control manager and change the Centurion Smart Control service startup type from Automatic toAutomatic (Delayed Start). Changing the service to Automatic (Delayed Start) will give the machine time register its IP address before listening for clients on all subsequent reboots.

 